Throughout this site we make reference to Connectable Areas, Dimensions, Pipe Sizes, Flow Rates and Rainfall Intensities. These by necessity vary, world wide. If you are interested in any product with such a specification, please either contact the 3P Partner in your country for the full Specification and/or for general Export Enquiries, please contact us for an immediate response. Thank you for your assistance.

Products Industrial Filters > 3P Volumefilter VF3 Article No. 1000800

Description

Rainwater filter for bigger roof areas. Filter for installation in a concrete ring (Ø 1200 mm). Normally standard concrete shafts are used. The filter can be delivered to the site yet pre-assembled in the shaft.

Two step cleaning system, therefore high level of filtering efficiency, independent of flow rate.

Due to the steep inclination of the filter cartridge the dirt is continuously cleaned away into the sewer. The connection to the sewer is installed at the shaft. The dirt falls down on the bottom of the shaft and is washed away with the next strong rainfall.

Relative connection capacity according to DIN 1986 for roof areas up to 1100 m². Because of a Bypass-Installation a bigger area can be connected.

Max. Flow Rate Sieve insert 4,5/sec = 16,2 m³ cleaned water per hour.

Inlet rainwater 2 x DN 200
Outlet into storage DN 150
Outlet into sewer DN 200
Height difference between inlet and outlet 320 mm.

The filter has to be cleaned depending on the contamination 1 - 2 times during the year.

How it works

  1. As water arrives the level builds up and overtops the filter lip, so ensuring it is distributed evenly across the whole width of the filter cascade.
  2. Pre cleaning through the cascades. Largest dirt particles are led across the primary filter cascades directly to the sewer.
  3. Pre filtered water then flows over the secondary filter sieve (Mesh size 0,4 x 1 mm). Due to the special mesh structure of the sieve, any dirt falls directly down onto the bottom of the shaft. In case of heavy rainfalls, the filter has more loss, as the water washes away the filtered dirt into the sewer.
  4. The cleaned water is being absorbed in the lower tank and directed through a tube DN 150 into the storage.
  5. Dirt goes to the sewer through the shaft.
  6. The 3P Volume Filter VF3 has only one fin unit. On the opposite a baffle is mounted.

Technical Data

Filter according to DIN 1989-2, Typ C

Connection inlet: 2 x DN 200
Outlet into storage: DN 150
Outlet into sewer: DN 200

Height difference between inlet and outlet 320 mm.

Material Filter corpus: stainless steel 4016
Material Filter sieve: stainless steel 1.4301
Mesh size: 0,4 x 1 mm

Legs = Thread rods M10 with screw nut made of stainless steel, Length 250 mm

Weight: 33,2 kg

A 670 mm
B 540 mm
C 525 mm
D 980 mm
E 320 mm
F 275 mm
G 880 mm

Example

Installation of a filter in a pilot shaft.

Example

Installation of the filter in front of several concrete tanks which are situated in a row.

Optimal installation

If the size of the roof or the diameters of the tubes should be vary from the specifications/requirements, you can make an installation according to the DIN as demonstrated below.

Advice

On demand the filter can be equipped with only one inlet. Please indicate in order. The hole then will be closed with a blind.

Advice

The 3P Volume Filter is equipped with only one fin unit. It can be converted into a VF4 afterwards.